Skip to content

Troubleshooting ​

Start with Project info: path, toolchains, and loaded modules. If those do not match, change Settings and click Reload in Project info.

Still stuck? Bug report with the version and a session export.

Look up project configuration ​

How to open it and what you see: Project info.

If Project info is empty, this folder did not load EB, DaVinci, ETAS, VCOS, or Neusar. Match the symptoms below.

Opened the wrong project ​

Check the path at the top of Project info. If it is wrong, close the project and open a project again from the welcome screen.

Settings changes did not apply ​

Click Reload in Project info, or close and reopen the project. Do not chat against stale paths.

EB Tresos ​

No EB card in Project info ​

  • The open folder must be the project root that contains .project
  • Settings → Install paths: tresos root (it contains bin\tresos_cmd.bat)
  • Settings → EB Tresos: project path and the modules to load
  • Return to Project info and Reload

Full steps: EB Tresos.

「EB Tresos path is not configured」 ​

Settings → Install paths, set the tresos root (e.g. C:\EB\tresos), save, then Reload in Project info.

Wrong module list ​

Modules in Project info come from include / exclude on Settings → EB Tresos. Reload, then confirm only the modules you want remain.

DaVinci Configurator ​

「DaVinci project not found」 or no DaVinci card ​

The open folder must contain *.dpa. See DaVinci Configurator.

verify unavailable ​

Need Core/DVCfgCmd.exe under the Configurator path. If Project info shows a SIP warning, fix SIP under Settings → Install paths.

GUI does not show latest config ​

Refresh or reopen the project in Configurator. Save the module from Project info first.

ETAS ISOLAR ​

「ETAS project not found」 or no ETAS card ​

Project root needs EcucValueCollection_Generated.arxml and .project. See ETAS ISOLAR.

verify missing param that generate auto-fills ​

On Settings → ETAS ISOLAR, add the parameter to Auto-assign params (e.g. CanIfTxPduId), then reload.

Wrong module list ​

Use Data ARXML exclude on Settings → ETAS ISOLAR to skip unwanted paths; leave empty to load all discovered files. Check Project info after reload.

VCOS Studio ​

No VCOS Studio card in Project info ​

Project root needs a *.vcosproject file. See VCOS Studio.

Wrong Python version ​

Studio requires Python 3.8. On Settings → Install paths, point Venv at the .venv created by init_env. AutoC does not create that environment.

Neusar ​

No Neusar card in Project info ​

Project root needs a *.nccf (or *.neusarprj) file. See Neusar.

Invalid Configurator path ​

  • Settings → Install paths: Configurator install root (it contains Bin/ — not Bin itself)
  • SIP comes with the install and is selected from the project file
  • Reload in Project info after saving

Configuration and references ​

Empty foreign-reference enums ​

ASW auto-scans the open project. Skip paths under Settings → ASW → Exclude patterns. See ASW.

Mixed project save did not sync ​

Open Settings → Module linkage and check the owner and each tool's configuration name. Save the owner. Container short names must match on both sides. See Module linkage.

AUTOSAR BSW / ASW AI configuration assistant